Uniaxial High Temperature ICP® Accelerometers(+365 ºF/+180 ºC)
![](https://static.wixstatic.com/media/b46d7f_f596b5eed1c043cfbaef9ab9bd85dc49~mv2.jpg/v1/fill/w_120,h_104,al_c,q_80,enc_auto/b46d7f_f596b5eed1c043cfbaef9ab9bd85dc49~mv2.jpg)
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4900 m/s² pk)
-
Broadband Resolution: 0.005 g rms (0.05 m/s² rms)
-
Frequency Range: (±5%) 1.0 to 10000 Hz
-
Sensing Element: Quartz
Model: 320C15
![](https://static.wixstatic.com/media/b46d7f_da1aa94c0b8a4baf835986167ed9a2c1~mv2.jpg/v1/fill/w_120,h_76,al_c,q_80,enc_auto/b46d7f_da1aa94c0b8a4baf835986167ed9a2c1~mv2.jpg)
Model: 300A12
-
Model 357M50 Accelerometer - survives 500 deg. F (260 deg. C)
-
Model 16950-01 Cable Assembly
-
Model 422M136 Charge Amplifier
-
System sensitivity is 10 mV/g
-
Frequency range is 10 to 10,000 Hz (+/- 5%)
Product Specification Sheet
![](https://static.wixstatic.com/media/b46d7f_c3b852516c734ebbb8081f7f693e6378~mv2.jpg/v1/fill/w_73,h_120,al_c,q_80,enc_auto/b46d7f_c3b852516c734ebbb8081f7f693e6378~mv2.jpg)
Model: 320C18
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4900 m/s² pk)
-
Broadband Resolution: 0.005 g rms (0.05 m/s² rms)
-
Frequency Range: (±5%) 1.0 to 10000 Hz
-
Sensing Element: Quartz
![](https://static.wixstatic.com/media/b46d7f_1ca6854b8a0c45ca97896d338bd6eef5~mv2.jpg/v1/fill/w_58,h_120,al_c,q_80,enc_auto/b46d7f_1ca6854b8a0c45ca97896d338bd6eef5~mv2.jpg)
Model: 320C20
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4900 m/s² pk)
-
Broadband Resolution: 0.006 g rms (0.06 m/s² rms)
-
Frequency Range: (±5%) 2.0 to 5000 Hz
-
Sensing Element: Quartz
![](https://static.wixstatic.com/media/b46d7f_69d3351ea8344a1c8fe3850815e02a55~mv2.jpg/v1/fill/w_112,h_120,al_c,q_80,enc_auto/b46d7f_69d3351ea8344a1c8fe3850815e02a55~mv2.jpg)
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4900 m/s² pk)
-
Broadband Resolution: 0.003 g rms (0.03 m/s² rms)
-
Frequency Range: (±5%) 1 to 6000 Hz
-
Sensing Element: Quartz
Model: 320C03
![](https://static.wixstatic.com/media/b46d7f_b8cf72d5df0f428e9d1ccd2d60da5388~mv2.jpg/v1/fill/w_96,h_120,al_c,q_80,enc_auto/b46d7f_b8cf72d5df0f428e9d1ccd2d60da5388~mv2.jpg)
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Measurement Range: ±50 g pk (±490 m/s² pk)
-
Broadband Resolution: 0.0003 g rms (0.003 m/s² rms)
-
Frequency Range: (±5%) 1 to 4000 Hz
-
Sensing Element: Quartz
Model: 320C33
Triaxial High Temperature ICP® Accelerometers(+365 ºF/+180 ºC)
-
Sensitivity: (±20%) 5 mV/g (0.51 mV/(m/s²))
-
Measurement Range: ±1000 g pk (±9810 m/s² pk)
-
Broadband Resolution: 0.003 g rms (0.03 m/s² rms)
-
Frequency Range: (±5%) 2 to 8000 Hz
-
Electrical Connector: Integral Cable
![](https://static.wixstatic.com/media/b46d7f_e288a8e463f44f9cb5a65d4cf141e6ed~mv2.jpg/v1/crop/x_0,y_20,w_104,h_86/fill/w_104,h_86,al_c,q_80,enc_auto/b46d7f_e288a8e463f44f9cb5a65d4cf141e6ed~mv2.jpg)
Model: HT356B01
Product Specification Sheet
![](https://static.wixstatic.com/media/b46d7f_3a055864f58f4af39d9c726d04693274~mv2.jpg/v1/fill/w_98,h_93,al_c,q_80,usm_0.66_1.00_0.01,enc_auto/b46d7f_3a055864f58f4af39d9c726d04693274~mv2.jpg)
Model: TLD339A34
-
Sensitivity: (±10%) 50 mV/g (5.1 mV/(m/s²))
-
Measurement Range: ±100 g pk (±980 m/s² pk)
-
Broadband Resolution: .005 g rms (.049 m/s² rms)
-
Frequency Range: (±5%) 2 to 5000 Hz
-
Electrical Connector: 1/4-28 4-Pin
Product Specification Sheet
![](https://static.wixstatic.com/media/b46d7f_ad7fa270c3234e67a9d1c53af8f79077~mv2.jpg/v1/fill/w_115,h_120,al_c,q_80,blur_3,enc_auto/b46d7f_ad7fa270c3234e67a9d1c53af8f79077~mv2.jpg)
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4905 m/s² pk)
-
Broadband Resolution: 0.008 g rms (0.078 m/s² rms)
-
Electrical Connector: 8-36 4-Pin
-
Sensing Element: UHT-12™
![](https://static.wixstatic.com/media/b46d7f_4a1379c01af44e7fb96b31781cb56720~mv2.jpg/v1/fill/w_96,h_96,al_c,q_80,usm_0.66_1.00_0.01,blur_3,enc_auto/b46d7f_4a1379c01af44e7fb96b31781cb56720~mv2.jpg)
-
Sensitivity: (±10%) 10 mV/g (1.0 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4900 m/s² pk)
-
Broadband Resolution: .003 g rms (.029 m/sec²rms)
-
Frequency Range: (±5%) 2 to 5000 Hz
-
Electrical Connector: 1/4-28 4-Pin
Model: 339A30
Model: TLD339A36
Product Specification Sheet
![](https://static.wixstatic.com/media/b46d7f_96d3a43671754ec5bf3c0b0b56bf950b~mv2.jpg/v1/fill/w_115,h_120,al_c,q_80,blur_3,enc_auto/b46d7f_96d3a43671754ec5bf3c0b0b56bf950b~mv2.jpg)
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4905 m/s² pk)
-
Broadband Resolution: 0.008 g rms (0.078 m/s² rms)
-
Frequency Range: (±5%) 2 to 6000 Hz (2 to 6000 Hz)
-
Electrical Connector: 8-36 4-Pin
Model: 339A31
![](https://static.wixstatic.com/media/b46d7f_1217b7fcbbe14cbab0ae7a327447e6a4~mv2.jpg/v1/crop/x_0,y_24,w_120,h_96/fill/w_120,h_96,al_c,q_80,blur_3,enc_auto/b46d7f_1217b7fcbbe14cbab0ae7a327447e6a4~mv2.jpg)
-
Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
-
Measurement Range: ±500 g pk (±4905 m/s² pk)
-
Broadband Resolution: .003 g rms (.029 m/s² rms)
-
Electrical Connector: 8-36 4-Pin
-
Sensing Element: UHT-12™